Cyrix-i 12/24V-120A intelligent combiner


View larger image

CODE: CYR010120000

Price: 55.00

 
Description
Send to friend
Reviews

Some battery combiners will disconnect a battery in case of a short but high amperage load. A battery combiner also may fail

to connect a large but discharged battery bank because the DC voltage immediately drops below the disengage value once

the batteries are connected.

The software of the Cyrix-i 12/24-100 does more than simply connect and disconnect based on battery voltage and with a

fixed time delay. The Cyrix-i 12/24-100 looks at the general trend (voltage increasing or decreasing) and reverses a previous

action only if the trend has reversed during a certain period of time. The time delay depends on the voltage deviation from the

trend.

12/24V auto ranging

The Cyrix-i 12/24-120 automatically detects system voltage.

No voltage loss

Cyrix battery combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage

loss so that the output voltage of alternators or battery chargers does not need to be increased.

Prioritising the starter battery

In a typical setup the alternator is directly connected to the starter battery. The accessory battery, and possibly also a bow

thruster and other batteries are each connected to the starter battery with Cyrix battery combiners. When a Cyrix senses that

the starter battery has reached the connect voltage it will engage, to allow for parallel charging of the other batteries.

Bidirectional voltage sensing and power supply from both batteries

The Cyrix senses the voltage of both connected batteries. It will therefore also engage if for example the accessory battery is

being charged by a battery charger.

The Cyrix-i 12/24-120 has a dual power supply. It will therefore also close if the voltage on one battery is too low to operate

the Cyrix.

In order to prevent unexpected operation during installation or when one battery has been disconnected, the Cyrix-i 12/24-

120 will not close if the voltage on one of the two battery connections is lower than 2V (12V battery) or 4V (24V battery).

Parallel connection in case of emergency

The Cyrix can also be engaged with a push button (Cyrix remains engaged during 30s) or a switch to connect batteries in

parallel manually.

This is especially useful in case of emergency when the starter battery is discharged or damaged.

 

New: intelligent battery monitoring to prevent unwanted switching


No posts found
 


Add new post

*
*

To ensure that a person, not an automated program, is filling this form, please enter the characters you see in this picture. All letters will be shown in their capitalized form.

  Redraw

Characters: 

  
*
  
  
*

To ensure that a person, not an automated program, is filling this form, please enter the characters you see in this picture. All letters will be shown in their capitalized form.

  Redraw

Characters: 

Loading...