Cyrix- i 24 / 48 v - 400amp intelligent combiner


View larger image

CODE: CYR020400000

Price: 234.00

 
Description
Send to friend
Reviews

Cyrix-i 200A-400A 24/48V

New: intelligent battery monitoring to prevent unwanted switching

Some battery combiners will disconnect a battery in case of a short but high amperage load. A

battery combiner also may fail to connect a large but discharged battery bank because the DC

voltage immediately drops below the disengage value once the batteries are connected.

The software of the Cyrix-i does more than simply connect and disconnect based on battery voltage

and with a fixed time delay. The Cyrix-i looks at the general trend (voltage increasing or decreasing)

and reverses a previous action only if the trend has reversed during a certain period of time. The

time delay depends on the voltage deviation from the trend.

In addition, four switch timing profiles can be chosen (see back page).

12/24V and 24/48V auto ranging

The Cyrix-i automatically detects system voltage.

No voltage loss

Cyrix battery combiners are an excellent replacement for diode isolators. The main feature is that

there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not

need to be increased.

Prioritising the starter battery

In a typical setup the alternator is directly connected to the starter battery. The accessory battery,

and possibly also a bow thruster and other batteries are each connected to the starter battery with

Cyrix battery combiners. When a Cyrix senses that the starter battery has reached the connect

voltage it will engage, to allow for parallel charging of the other batteries.

Bidirectional voltage sensing and power supply from both batteries

The Cyrix senses the voltage of both connected batteries. It will therefore also engage if for example

the accessory battery is being charged by a battery charger.

The Cyrix-i has a dual power supply. It will therefore also close if the voltage on one battery is too

low to operate the Cyrix.

In order to prevent unexpected operation during installation or when one battery has been

disconnected, the Cyrix-i will not close if the voltage on one of the two battery connections is lower

than 2V (12V battery), or 4V (24V battery) or 8V (48V battery).

Parallel connection in case of emergency

The Cyrix can also be engaged with a push button (Cyrix remains engaged during 30s) or a switch

to connect batteries in parallel manually.

This is especially useful in case of emergency when the starter battery is discharged or damaged.